Rectifier
  • SCR Electrolytic Rectifier
  • SCR electrolytic rectifier adopts SCR rectification technology. As a special electrolysis rectifier, this product is mainly used in electrochemistry, including...

Protable IGBT 12v 100a DC PCB Plate Plating Rectifier , DC Plating Power Supply

Input Voltage: 220V Phase: Single Phase
Control: Local Panel Control Cooling: Forced Air Cooling
Size: 420*310*145mm Weight: 9kg
Product Name: PCB Plate Plating Rectifier Accuracy: CC CV +-1%

small protable igbt 12v 100a DC PCB plate plating rectifier ,dc plating power supply

 

How to choose PCB plate plating rectifier ?

 

To select PCB plate plating rectifier has three requirements:
1, Meet the specifications required by plating process, including dc power supply power, waveform index, adjustable current and voltage range, etc.;
2, PCB plate plating power supply itself reliability power supply, which mainly refers to structure reasonable, security and line features, cooling methods;
3, DC power supply cost performance.

Determine what kind of PCB plate plating rectifier suitable for you:

Determining plating type and and what kind of dc power supply the plating tanks shall use is the implementation and the first important work in electroplating production. There are 2 methods to determine suitable dc power supply in the actual plating production:
One: according to plating liquid solution to determine volume current density;
Two: calculated according to the plating area to get plating current density per unit.

The so-called volume current density, it is based per liter of plating solution allowed to pass maximum current to adjust entire plating tank current intensity, to determine the maximum power supply output and the conventional output.

Example for choosing PCB plate plating rectifier

Copper is generally 0.2 ~ 0.3A/L;
Nickel is 0.1 ~ 2.5A/L;
Bright nickel plating is 0.3 ~ 0.35A/L;
Acid zinc is A/L;
Alkaline zinc up to 1.2 A/L;
Chrome is A/L.
Bright nickel plating as case shows, 600L bath maximum process current up to 0.3A/L × 600L = 180A, so choose 200A DC power supply is just fine.

If according to plating area volume also can calculate the max. current.
We take chrome plating as case: if it is 600L plating bath, at 60 ℃, maximum current density of 100A/dm2, the plating tank at full load setting as 10dm2, then the power required maximum output current of 100A/dm2 × 10dm2 = 1000A, that is, 1000A DC power supply, 18V rectifier power supply.

After determining power of DC power supply. Also need consider plating technical treatment process requirements and plating site condition to select waveform, cooling method, volume size, and corrosion resistance, etc., including cost factors.

GENRAL SEPCIFICATION small protable igbt 12v 100a DC PCB plate plating rectifier ,dc plating power supply

AC Input voltage 220V
frequency 50/60hz
phase 1 phase
output current 0~100a adjustable
voltage 0~12v adjustable
frequency 40khz
effiencicy ≥89%
voltage stability ≤1%
current stability ≤1%
Stabilization mode Current stabilization/Voltage stabilization (Switchable easily)
adjustment range Voltage/Current from 0-100% continuously adjustable within rated range
control part cooling system air cooling /water cooling/mixed water & air cooling
control method local panel control/remote control box/ PLC
Display contents Voltage meter/Current meter/Working/Over temp/Error, etc..
Protection method Input over voltage/Under voltage/Over current/Output short/Over heating self protection etc.
use environment Operating temperature -20-50℃
Ambient temperature 30-65℃
Ambient humidity ≤90%
Working loading

Full capacity operation, more than 1,000 meters above sea level, reduced load operation