Input Voltage: | 415V | Phase: | 3 Phase |
---|---|---|---|
Control Way: | PLC Control | Cooling: | Forced Air Cooling |
Size: | 715*485*860mm | Weight: | 80kg |
Accuracy: | CC CV +-1% | Output Voltage: | DC 0~125V Adjustable |
Output Current: | DC 0~150A Adjustable |
125V 150A PLC Control Anodizing Power Supply Air Cooling IGBT Rectifier
125V 150A DC anodizing PLC control air cooling igbt rectifier is widely used in aviation, aerospace, weapons, railways, electricity, electronics, copper, aluminum, sewage treatment, automobile manufacturing, shipbuilding, oil and other fields
• Anodizing: anodizing, hard anodizing
• Waste water treatment • Other DC Power Supply application field
• Recovery of Copper, Cobalt, Nickel, Cadmium, Zinc • and Bismuth from Electrolytic Copper Solution
GENRAL SEPCIFICATION 125V 150A DC anodizing PLC control air cooling igbt rectifier
AC Input | voltage | 415V |
frequency | 50/60hz | |
phase | 3 phase | |
output | current | 0~5000a optional |
voltage | 0~125V adjustable | |
frequency | 40khz | |
effiencicy | ≥89% | |
voltage stability | ≤1% | |
current stability | ≤1% | |
Stabilization mode | Current stabilization/Voltage stabilization (Switchable easily) | |
adjustment range | Voltage/Current from 0-100% continuously adjustable within rated range | |
control part | cooling system | air cooling /water cooling/mixed water & air cooling |
control method | local panel control/remote control box/ PLC | |
Display contents | Voltage meter/Current meter/Working/Over temp/Error, etc.. | |
Protection method | Input over voltage/Under voltage/Over current/Output short/Over heating self protection etc. | |
use environment | Operating temperature | -20-50℃ |
Ambient temperature | 30-65℃ | |
Ambient humidity | ≤90% | |
Working loading | Full capacity operation, more than 1,000 meters above sea level, reduced load operation |
OPTIONAL FEATURE for 125V 150A DC anodizing PLC control air cooling igbt rectifier
Reduced Ripple | Ripple is the amount of AC that appears as voltage fluctuations on the DC output. Because some metal finishing applications cannot tolerate excessive ripple levels, We offers power supplies with ripple as low as 3% of the operating set point |
Polarity Reversing | manual reverse or automatic reverse |
Digital Ampere-Hour / Minute Meter | achieve the current hour,current minute control,achieve the chemical solution automatically add |
Computer analog Interface | 0~10v,4~20mA,0~5V interface,achieve remote control for the 125V 150A DC anodizing PLC control air cooling igbt rectifier ,saving the cost |
PLC +HMI control | RS 485,Profibus,Profinet international standard interface |
multi-period Timer | Timers are available to turn the rectifier off, sound an alarm, illuminate a light (or any combination) at the end of a process cycle |
Cabinet: all the125V 150A DC anodizing PLC control air cooling igbt rectifier cabinet adopts magnetic cut links, reduce eddy current losses, and cabinet as a whole spray painting | Structure: 125V 150A DC anodizing PLC control air cooling igbt rectifier with reasonable structure design, isolated the inverter part and , rectification part , convenient to disassemble and maintenance |
Radiator: radiator capacity expanded 1.5 times,make sure better cooling effect | switch control way: adopt full bridge phase shifting soft switch,reduct IGBT loss,save engergy |
Main transformer: 125V 150A DC anodizing PLC control air cooling igbt rectifier adopts amorphous core,increase transformer efficiency,reduct the transformer temperature rise,cut the rectifier weight,improve the power supply stability, reliability | Core & Schottky diode: core capacity expanded 1.5 times schottky diode expands 4 times
|
Board : all control boards did anticorrosion treatment with imported three defense lacquer | IGBT: IGBT capacity expanded 3 times,make the power supply more reliable |
1,Placing 125V 150A DC anodizing PLC control air cooling igbt rectifier and keep the body stability; ensure good ventilation. |
2,Checking 125V 150A DC anodizing PLC control air cooling igbt rectifier out cover if any loosing. |
3,Connecting the machine shell to ground to prevent static electricity. |
4,Conecting the AC input wire |
5,Connecting the 125V 150A DC anodizing PLC control air cooling igbt rectifier DC output copper bars with the bath + - copper bars |
6,Connecting the remote control box,if local control ,skip this step |
7,Turn on air switch, then the fan starts to rotate and the power indicator light. |
8,Clockwise rotation adjustment button, voltmeter degree increases, working indicate light lighting. |
9,Adjust knob to maximum, then the voltmeter should indicate the rated voltage, current meter indicates the load volume accordingly. |
10,Disconnect the air switch, turn off the power |
Complete pre & after service for this 125V 150A DC anodizing PLC control air cooling igbt rectifier
Pre-Sales Service * Inquiry and consulting support within 12 hours. * Sample testing support. * View our Factory. | After-Sales Service * Training how to instal the machine, training how to use the Eelectroplating machine. * Engineers available to service machinery overseas. |
Keywords:
120v 200a Hard Anodizing Oxidation Pulse Rectifier With 4~20am Interface
12V 10000A Switch Mode Power Supply Plating Rectifier Water Cooled Remote Control